PVG32-4-20mA

Converts 4-20mA signal to voltage suitable for controlling DANFOSS PVG32 hydraulic proportional valves.
– Power supply (Vsup): 18-30Vdc / 75mA
– Analog input 4-20mA / 5Vmax
– Conversion Yin => Vout:
4mA => 22.5% Vsup
20mA => 77.5% Vsup
– Digital input “ENABLE”
– Insulation: Inputs – Output 1500V
– Ambient temperature: -20oC to + 50oC
– Housing: ABS 120x80x60mm / IP65


 PVG32-PWM

Converts PWM signal to voltage suitable for controlling DANFOSS PVG32 hydraulic proportional valves
– Power supply (Vsup): 15-33Vdc / 50mA
– PWM input: 15-33Vdc / Ton = 20% – 80%
– F = 100 – 1000 Hz
– Switching threshold: Vsup / 2
– PWMin conversion => Vout:
25% => 22.5% Total
75% => 77.5% Total
– Digital input “ENABLE”
– Ambient temperature: -20oC to + 50oC
– Housing: ABS 80x54x37mm / IP65


KEYENCODER

It is a computer keyboard emulator designed for the simple
connecting the PLC controller and the PC. Each of the 4 digital
input can be, with bridges, join the character from PS / 2 Code Set 1 or 2.
– PC Operating systems: WINDOWS 95/98 / NT / 2000 / XT
– Supports IBM PC / AT, IBM PS / 2 and compatible devices.
– Multimedia and ACPI keyboards, and Mini-Keyboard with Fn key.
– 16 character memory
– PC connection: PS2 and USB1.1 / 2.0 (with PS2 / USB adapter)
– USB1.1 communication speed
– Automatic PS2 / USB detection
– Power supply from PS2 / USB (4.5 – 5.5V)
– Ambient temperature: -10oC to + 50oC
-Housing: ABS 120x80x60mm / IP65


RAT-01

The set consists of a hermetically sealed HALL angle sensor,
booster magnetic screw and converter which as
the sensor versus the magnetic screw converts to 4-20mA
current signal.
Sensor:
– Housing: 48x31x6,5 mm / IP68 (Washable under pressure)
– Temp. environment: -40oC to + 130oC
– Vibration: 20 – 2000 Hz in all directions
– Shock: drop of 3m on concrete
– Lifespan: 10×106 rpm +/- 70o
– Distance sensor – screw: up to 5 mm
– Sensor – axle offset screw: up to 2 mm
– Sensor cable length 0.5m.
– Encouraging magnetic screw M10 / 1
– 4 wire connection
– Select +/- angle direction
Converter:
– Three-wire connection
– Setting the starting position (OFFSET)
– 4mA current setting. starting positions
– Setting the current to 20mA end position
– Power supply (Vsup): 15-33Vdc / 50mA
– Compliance output voltage: Vsup – 3V
– Output short circuit current: Imax = 25mA
– Ambient temperature: -20oC to + 50oC
– Housing: ABS 65x50x36mm / IP65


 AIRFLOW 1.0

Mass air flow sensor based on the difference measurement principle
temperatures before and after the heating element
– Two-way measurement
– Measuring range: +/- 1000 sccm
(Standard Cubic Centimeters per Moon)
– Three-wire connection
– Continuation:
– Yout for flow 0 sccm (4mA)
– Iout for maximum flow (20mA)
– Power supply (Vsup): 16-32Vdc / 50mA
– Compliance output voltage: Vsup – 3V
– Short circuit current: Imax = 25mA
– Ambient temperature: -20oC to + 50oC
– Housing: ABS 180x105x65mm (with glands) / IP65